Vacon nxp user manual i o boards

Manual boards vacon

Add: uqite10 - Date: 2020-12-13 21:49:00 - Views: 5956 - Clicks: 2421
/470093 /71-86ff2ec90fec /147 /291711-17

User guide - BC: VACON® OPTE2-E8 RS485 Board User Manual: English: Multiple : 01 Jan, : 7. The Vacon NXS or NXP AC drive is ready for operation. The most typical option board for NXL, OPT-AA, is specified in the User’s Manual, Chapter 10.

There are functions included that are required to achieve a smooth ride in the lift car. The control board can be powered externally (+24V) by connecting the external power source to bidirectional terminal 6 (see Table 6-9). 0 MB PDF Fact sheet – AM DrivePro® Remote Monitoring 769. · FAX. This manual is available in both paper and electronic editions. Before connecting the AC drive to mains make sure that the front and cable covers of the drive are closed. Vacon OPT-AF option vacon nxp user manual i o boards board to be used with Vacon NXP control board in NX family products.

Manufacturer&39;s name: Vacon Plc Manufacturer&39;s address: P. Vacon Nxs User Manual - cinurl. The VACON NXP supports both induction and permanent magnet motors in open and closed loop control modes. There are five board slots (labelled A to E ) on the control board of NXS and NXP (See User’s Manual, Chapter 6. 1): The connectability of different option boards to different slots vacon nxp user manual i o boards depends greatly.

6 KB PDF Fact sheet – AM DrivePro® Spare Parts 525. Select the NXP Lift Application in menu M6 on page S6. The I/O interface table includes the most commonly needed signals in lift applications. Do not even open the cabinet door before this time has expired. Vacon NX IO Boards User Manual Vacon NX Door Keypad Mounting Instr. With fast fieldbus options and exceptional programming flexibility, your NXP is easily integrated into any plant’s automation system. The control board of NXL includes fixed standard I/O and one place for option boards (see NXL User Manual of NXL). The control board of NXL includes fixed standard I/O and one place for option boards (see NXL User Manual of NXL).

There are five board slots (labelled A to E) on the control board of NXS and NXP (See NXS/P User Manual): The connectability of different option boards to different slots depends greatly on the type of the board. The NXC is a modular product intended for use in all applications where reliability and high availability is appreciated. 1 Ohjauskortin korttipaikat (Vacon NXS ja Vacon NXP) Kuva 1-1. Wait 5 more minutes before doing any work on Vacon NX connections. The most typical option board for NXL, OPT-AA, is specified in the User™s Manual, Chapter 10. 1 vacon • 4 General information. However, the relay outputs and other I/O-terminals may have a dangerous control voltage present even when the AC drive is disconnected from mains. Safe Torque Off, Safe Stop 1 (Specified in EN:).

See also the Vacon I/O boards manual. 2 MB PDF: User guide - BC: VACON® OPTEA/E9 Ethernet Board User G. 1 MB PDF: Safety guide - BH.

The same control board is used in all VACON NXP drives, allowing the maximum utilization of. Manual OPT-C2 manual – Modbus / N2 OPT-C3manual – Profibus DP OPT-C4manual – Lonworks OPT-C6manual. NXS and NXP ® The control board is situated inside the control unit of the VACON NX AC drive. The I/O boards mounted at the factory are indicated in the type code. The hardware will be always the Vacon NXP converter. The NXP Lift Application can be used with modern Lift systems. However, the control boards of these types differ from each other to some extent which means that the use of some I/O boards in different Vacon frequency converter types may be restricted. OPT-AF option board, VB00328H (or newer revision) NXP control board, VB00761B (or newer revision) Product Safety Functions.

The control board of NXL includes fixed standard I/O and one place for option boards (see User’s Manual of NXL, Chapter 6. El convertidor de frecuencia Vacon NXS o NXP está listo para funcionar. NX Retrofit Kit Inst. From application notes and user guides to data sheets and errata, discover the NXP Complete library of technical and support documentation. 2 • vacon Telephone• FaxINDEX Document code. English: Multiple : 01 Jun, : 8. VACON® NXP Air Cooled drives offer precision and power to applications that require a robust and dynamic performance.

The control board of NXL includes fixed standard I/O and one place for option boards (see User™s Manual of NXL, Chapter 6. Unit Manual Vacon NXP System Drive Hardware Manual Vacon NXP HXM120 Cool. The most typical option board for NXL, OPT-AA, is specified in the NXL User Manual. Vacon NX OPTBC Resolver Board Manual Vacon NX OPTAK OPTBE ENDAT SSI SIN-COS Board User Manual Vacon NXP HXT070 Cool.

Digital Inputs: 6Digital Outputs: 1Analogue Inputs: 2 (mA/V, -10 to +10V)Analogue Outputs: 1 (mA/V)Reference Outputs: +10V for Analogue Inputs, +24V for Digital Inputs. Page 74 74 • vacon description of parameters Fieldbus reference minimum scaling (2. • FaxAT LEAST THE FOLLOWING STEPS OF THE START-UP QUICK GUIDE MUST BE. The I/O boards are usually interchangeable between different Vacon types, i. 1 Board slots on th e control board of Vacon NXS and NXP Figure 1. VACON · 4 START-UP QUICK GUIDE TEL. Vacon Standard I/O board (Vanished) with digital inputs/outputs and analogue inputs/outputs for expansion slot A of NXS/NXP Variable Frequency Drives. Box 25 Runsorintie 7 FIN-65381 Vaasa Finland We hereby declare that the safety functions of the following product Product name: Vacon OPT-AF option board to be used with Vacon NXP control board in NX family products.

Unit Manual Vacon NXP Liquid Cooled Enclosed Dr. Product Identification. 0 KB PDF Fact sheet – AM DrivePro® Preventive Maintenance 1. Vacon Plc no se responsabiliza de la utilización de los convertidores de frecuencia si no se siguen estas instrucciones. Board slots on control board of the VACON® NXS and NXP The control board is situated inside the control unit of the VACON ® NX AC drive. Ohjauskortilla on viisi kirjaimin A–E merkittyä korttipaikkaa: Laajennuskortin (NXS vacon nxp user manual i o boards ja NXP) tyypistä riippuu, mihin korttipaikkaan sen voi liittää ( Ks. However, the relay outputs and other I/O-terminals may have a dangerous control voltage present even when Vacon NX is disconnected from mains. VACON · 4 GUÍA DE INICIO RÁPIDO TEL.

24-hour support:• Email: 2 Basic parameters (Control keypad: Menu P2 P2. For more information on the option boards, see Vacon NX option board manual (ud741). VACON NXP Liquid Cooled Documents Type Name Download File type Fact sheet – AM DrivePro® Extended Warranty 771. vacon nx ac drives nxc drives user manual vacon • 1 Tel.

Manufacturer Part number is OPT-A1-V ( OPTA1 ) / ( NXOPT1 ). 1) Fieldbus reference maximum scaling (2. the frequency converter (see Vacon NX User&39;s Manual, Chapter 6. Board slots on control board of the Vacon NXS and NXP The control board is situated inside the control unit of the Vacon NX frequency converter. 1 Board slots on the control board of VACON® NXS and NXP Figure 1. We recommend that you carefully study these instructions before powering up the frequency converter for the first time. The User&39;s Manual will provide you with the necessary information about the installation, commissioning and operation of Vacon NX Frequency Converters.

2) Use these two parameters to scale the fieldbus reference. Available in a complete power range up to 2 MW, they are provided as wall-mounted, standalone enclosed and IP00 modules. vacon nxp ac drives ip00 modules frames fr10 to fr14 installation manual.

Note: If the selected value is greater than the actual number of used PT100 inputs, the display will read 200ºC. 24-hour support• Email: INTRODUCTION The Vacon NXC is a product range of free standing enclosed frequency vacon nxp user manual i o boards converters for the high power range. Ohjauskortin korttipaikat (Vacon NXS ja Vacon NXP) Ohjauskortti sijaitsee Vacon NX-taajuusmuuttajan ohjausosan sisällä. Vacon NXP is the smart drive of choice.

• faxcontents vacon nxc user’s manual index 1 safety 2 introduction 3 receipt of delivery. The control I/O-terminals are isolated from the mains potential. Information on the installation of the drive in a cabinet can be found in manuals &39;NXP Frequency Converters, IP00 Module Installation, Frames FR10 to FR14 (ud00908) as well as Frequency Inverter (UD01063) and Active Front End (UD01190) manuals. The User&39;s Manual will provide you with the necessary information about the installation, commissioning and operation of Vacon NX Liquid-C ooled drives. VACON® Programming tool can be used to improve performance and create cost savings by integrating customer-specific functionality into the drive. There are five board slots (labelled A to E) on the control board of NXS and NXP (See NXS/P User Manual): The. Vacon NXP is a premium air-cooled AC drive for use in all applications where reliability, robust performance, precision and power are required.

The I/O boards are usually in terchangeable between different Vacon types, i. Man Vacon NX OPTBC Resolver Board Manual Vacon NX OPTAK OPTBE ENDAT SSI SIN-COS Board User Manual Vacon NXP HXT070 Cool. Vacon Plc is not responsible if you use the AC drives against the instructions. If you we want to control an induction motor in Close Loop, will need Encoder Boards NXOPTA4 or NXOPTA5. If motor to control is Permanent Magnets, then wil be necessary to use NXOPTBB if the Encoder used is an EnDat (Heidenhein ECN 413 or 1313), or NXOPTAK if the Encoder is Sin/Cos. 4 KB PDF Certificate – BG EC declarat.

1) Code Parameter Min Max Unit Default Cust ID Note. Manual, Neutral NX Cable accessories FR4-8, MF4-6 Vacon NXS NXP Flange Mounting FR7-9 Man Vacon NXS NXP Flange Mount Kit F4-6 Inst.

Vacon nxp user manual i o boards